Definition: Every NFRC certified window or door is given a U factor, a score showing the rate at which indoor heat is lost through the complete unit, so lower scores mean a warmer home on cold days.

What is U-factor?

U-factor measures the rate of heat loss through a window, in Btu per hour per square foot per degree Fahrenheit. The National Fenestration Rating Council (NFRC) rates the whole unit, glass, spacer and frame together, so it reflects the window as built rather than the glass alone.

The U.S. Department of Energy notes that U-factor is the inverse of R-value (R equals 1 divided by U). ENERGY STAR describes typical window U-factors from 0.25 to 1.25.

Why it matters

ENERGY STAR sets a maximum U factor for each climate zone. Under Version 7.0, windows must reach 0.25 or lower in the North-Central zone and 0.28 or lower in the South-Central zone, and zone assignments are set by county. The NFRC label on every certified window lists its U factor, so you can compare quotes on the same number.

NFRC points out that its ratings do not account for installation, so a well rated window still needs a sealed, flashed and insulated opening to deliver that number in your home.

What lowers a U-factor

  • A second pane: DOE says double glazing cuts heat loss by more than half compared with a single pane.
  • Low E coatings, which reduce radiant heat transfer.
  • Argon or krypton gas fill in the sealed space.
  • Warm-edge spacers, which DOE says lower the U-factor by about 0.02.
  • Frame materials and designs that conduct less heat.

Because the rating covers the whole unit, two windows with the same glass can have different U-factors if their frames differ.

Reading U-factor with the other ratings

U-factor tells you about heat loss. Solar heat gain coefficient tells you about solar heat coming in, and air leakage tells you how tightly the unit seals. Performance grade separately covers structural, air and water testing. A window can score well on one and less well on another, so compare the full label.

Checking the label

NFRC certified windows carry a temporary label with the U-factor and other ratings. NFRC notes that it does not sell windows, and a window without the label is not considered certified. ENERGY STAR adds that its qualification is based on U-factor and SHGC ratings only, and that the U-factor must be certified and listed on the label.

Learn more

These pages cover installation and testing that affect real performance.

Related Eastern Shore Window & Door services

Frequently asked questions

Is a lower U-factor better?

Yes. A lower U-factor means less heat escapes through the window in cold weather.

How is U-factor related to R-value?

They are inverses. The U.S. Department of Energy notes that R-value equals 1 divided by U-factor, so a U-factor of 0.25 equals about R-4.

Does the U-factor include the frame?

Yes. NFRC rates the whole window, including frame, spacer and glass, which is why NFRC numbers are more useful than glass-only figures.

What is a typical U-factor for a window?

ENERGY STAR describes typical window U-factors from 0.25 to 1.25. Lower numbers come from multiple panes, Low E coatings, gas fills and better frames.